Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.706
Filtrar
1.
Comput Methods Programs Biomed ; 249: 108145, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38582038

RESUMO

BACKGROUND AND OBJECTIVE: Obstetricians use Cardiotocography (CTG), which is the continuous recording of fetal heart rate and uterine contraction, to assess fetal health status. Deep learning models for intelligent fetal monitoring trained on extensively labeled and identically distributed CTG records have achieved excellent performance. However, creation of these training sets requires excessive time and specialist labor for the collection and annotation of CTG signals. Previous research has demonstrated that multicenter studies can improve model performance. However, models trained on cross-domain data may not generalize well to target domains due to variance in distribution among datasets. Hence, this paper conducted a multicenter study with Deep Semi-Supervised Domain Adaptation (DSSDA) for intelligent interpretation of antenatal CTG signals. This approach helps to align cross-domain distribution and transfer knowledge from a label-rich source domain to a label-scarce target domain. METHODS: We proposed a DSSDA framework that integrated Minimax Entropy and Domain Invariance (DSSDA-MMEDI) to reduce inter-domain gaps and thus achieve domain invariance. The networks were developed using GoogLeNet to extract features from CTG signals, with fully connected, softmax layers for classification. We designed a Dynamic Gradient-driven strategy based on Mutual Information (DGMI) to unify the losses from Minimax Entropy (MME), Domain Invariance (DI), and supervised cross-entropy during iterative learning. RESULTS: We validated our DSSDA model on two datasets collected from collaborating healthcare institutions and mobile terminals as the source and target domains, which contained 16,355 and 3,351 CTG signals, respectively. Compared to the results achieved with deep learning networks without DSSDA, DSSDA-MMEDI significantly improved sensitivity and F1-score by over 6%. DSSDA-MMEDI also outperformed other state-of-the-art DSSDA approaches for CTG signal interpretation. Ablation studies were performed to determine the unique contribution of each component in our DSSDA mechanism. CONCLUSIONS: The proposed DSSDA-MMEDI is feasible and effective for alignment of cross-domain data and automated interpretation of multicentric antenatal CTG signals with minimal annotation cost.


Assuntos
Cardiotocografia , Monitorização Fetal , Gravidez , Feminino , Humanos , Cardiotocografia/métodos , Entropia , Monitorização Fetal/métodos , Contração Uterina , Frequência Cardíaca Fetal/fisiologia
2.
Nurs Womens Health ; 28(2): e1-e39, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38363259

RESUMO

Intermittent auscultation (IA) is an evidence-based method of fetal surveillance during labor for birthing people with low-risk pregnancies. It is a central component of efforts to reduce the primary cesarean rate and promote vaginal birth (American College of Obstetricians and Gynecologists, 2019; Association of Women's Health, Obstetric and Neonatal Nurses, 2022a). The use of intermittent IA decreased with the introduction of electronic fetal monitoring, while the increased use of electronic fetal monitoring has been associated with an increase of cesarean births. This practice monograph includes information on IA techniques; interpretation and documentation; clinical decision-making and interventions; communication; education, staffing, legal issues; and strategies to implement IA.


Assuntos
Monitorização Fetal , Trabalho de Parto , Gravidez , Recém-Nascido , Feminino , Humanos , Monitorização Fetal/métodos , Frequência Cardíaca Fetal , Auscultação/métodos , Cardiotocografia/métodos
3.
Curr Opin Anaesthesiol ; 37(3): 285-291, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38390901

RESUMO

PURPOSE OF REVIEW: Nonobstetric surgery during pregnancy is associated with maternal and fetal risks. Several physiologic changes create unique challenges for anesthesiologists. This review highlights physiologic changes of pregnancy and presents clinical recommendations based on recent literature to guide anesthetic management for the pregnant patient undergoing nonobstetric surgery. RECENT FINDINGS: Nearly every anesthetic technique has been safely used in pregnant patients. Although it is difficult to eliminate confounding factors, exposure to anesthetics could endanger fetal brain development. Perioperative fetal monitoring decisions require an obstetric consult based on anticipated maternal and fetal concerns. Given the limitations of fasting guidelines, bedside gastric ultrasound is useful in assessing aspiration risk in pregnant patients. Although there is concern about appropriateness of sugammadex for neuromuscular blockade reversal due its binding to progesterone, preliminary literature supports its safety. SUMMARY: These recommendations will equip anesthesiologists to provide safe care for the pregnant patient and fetus undergoing nonobstetric surgery.


Assuntos
Anestesia , Feto , Humanos , Gravidez , Feminino , Anestesia/métodos , Anestesia/efeitos adversos , Anestesia/normas , Feto/efeitos dos fármacos , Feto/cirurgia , Anestésicos/efeitos adversos , Anestésicos/administração & dosagem , Monitorização Fetal/métodos , Monitorização Fetal/normas , Complicações na Gravidez/prevenção & controle , Guias de Prática Clínica como Assunto , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Anestesia Obstétrica/métodos , Anestesia Obstétrica/efeitos adversos , Anestesia Obstétrica/normas
4.
Crit Rev Biomed Eng ; 52(2): 1-14, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38305274

RESUMO

Combined the improved fast independent component analysis (FastICA) algorithm with the singular value decomposition algorithm, a single-channel fetal electrocardiogram (fECG) extraction method is proposed. First, the improved FastICA algorithm is used to estimate the maternal ECG component from a single-channel abdominal signal of pregnant women using an overrelaxation factor. Then, a preliminary estimate of the fECG signal is obtained by subtracting from the single-channel abdominal signal. Subsequently, the singular value decomposition algorithm is used to denoise the preliminarily estimated fECG signal to obtain a high signal-to-noise ratio. In addition, in the singular value decomposition algorithm for fetal arrhythmia, an improved method for constructing the ECG signal reconstruction matrix is proposed. Finally, the fECG extraction experiments on synthetic abdominal signals and actual abdominal signals (data from 49 abdominal channels sourced from DAISY database and the non-invasive fECG database in PhysioNet) are carried out. The experimental results show that the method in this paper can effectively improve the signal-to-noise ratio and the accuracy of fECG signal extraction, and is suitable for maternal or fetal arrhythmias. Compared with the FastICA algorithm, the signal-to-noise ratio of the fECG signal extracted by the method in this paper is improved by about 5 dB, and the accuracy of fECG extraction in the PhysioNet database can reach 96.54%.


Assuntos
Monitorização Fetal , Processamento de Sinais Assistido por Computador , Feminino , Gravidez , Humanos , Monitorização Fetal/métodos , Eletrocardiografia/métodos , Algoritmos , Razão Sinal-Ruído
5.
Acta Obstet Gynecol Scand ; 103(5): 980-991, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38229258

RESUMO

INTRODUCTION: In clinical practice, fetal heart rate monitoring is performed intermittently using Doppler ultrasound, typically for 30 minutes. In case of a non-reassuring heart rate pattern, monitoring is usually prolonged. Noninvasive fetal electrocardiography may be more suitable for prolonged monitoring due to improved patient comfort and signal quality. This study evaluates the performance and patient experience of four noninvasive electrocardiography devices to assess candidate devices for prolonged noninvasive fetal heart rate monitoring. MATERIAL AND METHODS: Non-critically sick women with a singleton pregnancy from 24 weeks of gestation were eligible for inclusion. Fetal heart rate monitoring was performed during standard care with a Doppler ultrasound device (Philips Avalon-FM30) alone or with this Doppler ultrasound device simultaneously with one of four noninvasive electrocardiography devices (Nemo Fetal Monitoring System, Philips Avalon-Beltless, Demcon Dipha-16 and Dräger Infinity-M300). Performance was evaluated by: success rate, positive percent agreement, bias, 95% limits of agreement, regression line, root mean square error and visual agreement using FIGO guidelines. Patient experience was captured using a self-made questionnaire. RESULTS: A total of 10 women were included per device. For fetal heart rate, Nemo performed best (success rate: 99.4%, positive percent agreement: 94.2%, root mean square error 5.1 BPM, bias: 0.5 BPM, 95% limits of agreement: -9.7 - 10.7 BPM, regression line: y = -0.1x + 11.1) and the cardiotocography tracings obtained simultaneously by Nemo and Avalon-FM30 received the same FIGO classification. Comparable results were found with the Avalon-Beltless from 36 weeks of gestation, whereas the Dipha-16 and Infinity-M300 performed significantly worse. The Avalon-Beltless, Nemo and Infinity-M300 closely matched the performance of the Avalon-FM30 for maternal heart rate, whereas the performance of the Dipha-16 deviated more. Patient experience scores were higher for the noninvasive electrocardiography devices. CONCLUSIONS: Both Nemo and Avalon-Beltless are suitable devices for (prolonged) noninvasive fetal heart rate monitoring, taking their intended use into account. But outside its intended use limit of 36 weeks' gestation, the Avalon-Beltless performs less well, comparable to the Dipha-16 and Infinity-M300, making them currently unsuitable for (prolonged) noninvasive fetal heart rate monitoring. Noninvasive electrocardiography devices appear to be preferred due to greater comfort and mobility.


Assuntos
Cardiotocografia , Determinação da Frequência Cardíaca , Gravidez , Feminino , Humanos , Cardiotocografia/métodos , Monitorização Fetal/métodos , Eletrocardiografia , Frequência Cardíaca Fetal/fisiologia , Avaliação de Resultados da Assistência ao Paciente
6.
Enferm. glob ; 23(73): 68-94, ene. 2024. ilus, graf, tab
Artigo em Espanhol | IBECS | ID: ibc-228888

RESUMO

Introducción: El vínculo madre-feto juega un papel importante en la atención del embarazo, impactando los resultados del nacimiento. El monitoreo del movimiento fetal es una competencia fundamental para que las mujeres embarazadas lo hagan de manera independiente. Objetivo: Producir monitoreo audiovisual del movimiento fetal independiente y probar su efectividad en el apego materno-fetal y los resultados del parto. Métodos: La etapa I, desarrollo de Monitoreo de Bienestar Fetal Audiovisual, con estudio de literatura, etapas, desarrollo de escenarios, creación de audiovisuales, prueba de validez de expertos. La etapa 2 probó la efectividad de los medios audiovisuales sobre el apego materno-fetal con el instrumento Inventario de Apego Prenatal y los resultados del nacimiento a partir del peso del bebé al nacer. Diseño de un verdadero enfoque experimental de grupo de control pretest-postest. Muestras de mujeres embarazadas con antecedentes de atención prenatal en el Centro de Salud Kasihan II, Bantul, Yogyakarta, Indonesia con los siguientes criterios: embarazo único, normal, edad gestacional de 28 a 36 semanas. Los encuestados de 60 sujetos se dividieron en grupos experimentales y de control. Los datos normales se probaron mediante la prueba t pareada, la prueba t independiente y MANOVA. Resultados: Puntaje de prueba de validez de experto en contenido 81% muy válido, puntaje de validez de experto en medios 80.33%, válido. La aplicación audiovisual mostró los resultados de la prueba t pareada, tanto en el grupo experimental como en el control hubo diferencias en el pretest y postest, P<0.05. La prueba t de muestra independiente P < 0,05 y los resultados MANOVA simultáneos mostraron una puntuación de apego materno-fetal y un resultado del nacimiento P < 0,05 (AU)


Introduction: The mother-fetus bond plays an important role in pregnancy care, impacting birth outcomes. Monitoring fetal movement is a fundamental competence for pregnant women to do independently. Objective: to produce audiovisual monitoring of independent fetal movement and prove its effectiveness on maternal-fetal attachment and birth outcomes. Methods: Phase I, developing Audiovisual Fetal Well-being Monitoring, with literature study steps, developing scenarios, creating audiovisuals, testing the validity of experts. Stage 2 tested the effectiveness of audiovisual media on maternal-fetal attachment with the Prenatal Attachment Inventory instrument and birth outcomes from infant birth weight. Design of true experimental pretest-posttest control group approach. Samples of pregnant women with a history of antenatal care at the Kasihan II Health Center, Bantul, Yogyakarta, Indonesia with the following criteria: single pregnancy, normal, gestational age 28-36 weeks. Respondents of 60 subjects were divided into experimental and control groups. Normal data were tested by paired t test, independent t-test and MANOVA. Results: Content expert validity test score 81% very valid, media expert validity score 80.33%, valid. The audiovisual application showed the results of the paired t-test, both in the experimental and control groups there were differences in pretest and posttest, P <0.05. Independent sample t-test P < 0.05 and simultaneous MANOVA results showed maternal-fetal attachment score and birth outcome P < 0.05. Conclusion: Independent monitoring of fetal well-being using audiovisual media simultaneously affects the increase in maternal-fetal attachment scores and birth outcomes so it is recommended that second trimester pregnant women be taught techniques for counting fetal movements and practicing them routinely (AU)


Assuntos
Humanos , Feminino , Gravidez , Recém-Nascido , Monitorização Fetal/métodos , Relações Materno-Fetais , Resultado da Gravidez , Análise Multivariada
7.
Acta Obstet Gynecol Scand ; 103(1): 68-76, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37890863

RESUMO

INTRODUCTION: It is a shortcoming of traditional cardiotocography (CTG) classification table formats that CTG traces are frequently classified differently by different users, resulting in poor interobserver agreements. A fast-and-frugal tree (FFTree) flow chart may help provide better concordance because it is straightforward and has clearly structured binary questions with understandable "yes" or "no" responses. The initial triage to determine whether a fetus is suitable for labor when utilizing fetal ECG ST analysis (STAN) is very important, since a fetus with restricted capacity to respond to hypoxic stress may not generate STAN events and therefore may become falsely negative. This study aimed to compare physiology-focused FFTree CTG interpretation with FIGO classification for assessing the suitability for STAN monitoring. MATERIAL AND METHODS: A retrospective study of 36 CTG traces with a high proportion of adverse outcomes (17/36) selected from a European multicenter study database. Eight experienced European obstetricians evaluated the initial 40 minutes of the CTG recordings and judged whether STAN was a suitable fetal surveillance method and whether intervention was indicated. The experts rated the CTGs using the FFTree and FIGO classifications at least 6 weeks apart. Interobserver agreements were calculated using proportions of agreement and Fleiss' kappa (κ). RESULTS: The proportions of agreement for "not suitable for STAN" were for FIGO 47% (95% confidence interval [CI] 42%-52%) and for FFTree 60% (95% CI 56-64), ie a significant difference; the corresponding figures for "yes, suitable" were 74% (95% CI 71-77) and 70% (95% CI 67-74). For "intervention needed" the figures were 52% (95% CI 47-56) vs 58% (95% CI 54-62) and for "expectant management" 74% (95% CI 71-77) vs 72% (95% CI 69-75). Fleiss' κ agreement on "suitability for STAN" was 0.50 (95% CI 0.44-0.56) for the FIGO classification and 0.57 (95% CI 0.51-0.63) for the FFTree classification; the corresponding figures for "intervention or expectancy" were 0.53 (95% CI 0.47-0.59) and 0.57 (95% CI 0.51-0.63). CONCLUSIONS: The proportion of agreement among expert obstetricians using the FFTree physiological approach was significantly higher compared with the traditional FIGO classification system in rejecting cases not suitable for STAN monitoring. That might be of importance to avoid false negative STAN recordings. Other agreement figures were similar. It remains to be shown whether the FFTree simplicity will benefit less experienced users and how it will work in real-world clinical scenarios.


Assuntos
Eletrocardiografia , Monitorização Fetal , Triagem , Feminino , Humanos , Gravidez , Cardiotocografia/métodos , Eletrocardiografia/métodos , Monitorização Fetal/métodos , Feto , Frequência Cardíaca Fetal/fisiologia , Variações Dependentes do Observador , Estudos Retrospectivos
8.
Aust N Z J Obstet Gynaecol ; 64(1): 77-79, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37702257

RESUMO

Monitoring the fetal heartbeat underpins assessment of fetal wellbeing in labour. Although commonly employed in clinical practice, shortcomings remain. A recent review of clinical practice guidelines highlights the variation in definitions of the fetal heart rate that will lead to differences in interpretation. Will intrapartum care be improved by greater consensus around clinical practice guidelines through rationalisation or refinement of guidelines, or will the future see this technique replaced by more accurate forms of fetal monitoring?


Assuntos
Cardiotocografia , Trabalho de Parto , Gravidez , Feminino , Humanos , Cardiotocografia/métodos , Determinação da Frequência Cardíaca , Monitorização Fetal/métodos , Previsões , Frequência Cardíaca Fetal
9.
Acta Obstet Gynecol Scand ; 103(3): 437-448, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38093630

RESUMO

INTRODUCTION: ST waveform analysis (STAN) was introduced as an adjunct to cardiotocography (CTG) to improve neonatal and maternal outcomes. The aim of the present study was to quantify the efficacy of STAN vs CTG and assess the quality of the evidence using GRADE. MATERIAL AND METHODS: We performed systematic literature searches to identify randomized controlled trials and assessed included studies for risk of bias. We performed meta-analyses, calculating pooled risk ratio (RR) or Peto odds ratio (OR). We also performed post hoc trial sequential analyses for selected outcomes to assess the risk of false-positive results and the need for additional studies. RESULTS: Nine randomized controlled trials including 28 729 women were included in the meta-analysis. There were no differences between the groups in operative deliveries for fetal distress (10.9 vs 11.1%; RR 0.96; 95% confidence interval [CI] 0.82-1.11). STAN was associated with a significantly lower rate of metabolic acidosis (0.45% vs 0.68%; Peto OR 0.66; 95% CI 0.48-0.90). Accordingly, 441 women need to be monitored with STAN instead of CTG alone to prevent one case of metabolic acidosis. Women allocated to STAN had a reduced risk of fetal blood sampling compared with women allocated to conventional CTG monitoring (12.5% vs 19.6%; RR 0.62; 95% CI 0.49-0.80). The quality of the evidence was high to moderate. CONCLUSIONS: Absolute effects of STAN were minor and the clinical significance of the observed reduction in metabolic acidosis is questioned. There is insufficient evidence to state that STAN as an adjunct to CTG leads to important clinical benefits compared with CTG alone.


Assuntos
Acidose , Cardiotocografia , Gravidez , Recém-Nascido , Feminino , Humanos , Cardiotocografia/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Sofrimento Fetal/diagnóstico , Eletrocardiografia/métodos , Acidose/diagnóstico , Acidose/prevenção & controle , Monitorização Fetal/métodos , Frequência Cardíaca Fetal
10.
Biomed Phys Eng Express ; 10(2)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38118183

RESUMO

Intrapartum fetal hypoxia is related to long-term morbidity and mortality of the fetus and the mother. Fetal surveillance is extremely important to minimize the adverse outcomes arising from fetal hypoxia during labour. Several methods have been used in current clinical practice to monitor fetal well-being. For instance, biophysical technologies including cardiotocography, ST-analysis adjunct to cardiotocography, and Doppler ultrasound are used for intrapartum fetal monitoring. However, these technologies result in a high false-positive rate and increased obstetric interventions during labour. Alternatively, biochemical-based technologies including fetal scalp blood sampling and fetal pulse oximetry are used to identify metabolic acidosis and oxygen deprivation resulting from fetal hypoxia. These technologies neither improve clinical outcomes nor reduce unnecessary interventions during labour. Also, there is a need to link the physiological changes during fetal hypoxia to fetal monitoring technologies. The objective of this article is to assess the clinical background of fetal hypoxia and to review existing monitoring technologies for the detection and monitoring of fetal hypoxia. A comprehensive review has been made to predict fetal hypoxia using computational and machine-learning algorithms. The detection of more specific biomarkers or new sensing technologies is also reviewed which may help in the enhancement of the reliability of continuous fetal monitoring and may result in the accurate detection of intrapartum fetal hypoxia.


Assuntos
Hipóxia Fetal , Trabalho de Parto , Gravidez , Feminino , Humanos , Hipóxia Fetal/diagnóstico , Reprodutibilidade dos Testes , Monitorização Fetal/métodos , Cardiotocografia/métodos
11.
Artigo em Inglês | MEDLINE | ID: mdl-38082674

RESUMO

Non-invasive fetal electrocardiography (NI-fECG) is a promising technique for continuous fetal heart rate (fHR) monitoring. However, the weak amplitude of the fetal electrocardiogram (fECG), and the presence of the dominant maternal ECG (mECG), makes it highly challenging to detect the fetal QRS (fQRS) complex, which is needed to obtain the fHR. This paper proposes a new method for automated fQRS detection from single-channel NI-fECG signals, without cancelling out the mECG. The proposed method leverages the different spectral behaviour exhibited by mECG and fECG signals. Fetal R-peaks are detected using a hybrid combination of k-means clustering with time and time-frequency features extracted from pre-processed NI-fECG recordings. The performance of our method is evaluated using real and synthetic signals from publicly available datasets, achieving a best of 96.3% sensitivity and 90.4% F1 score. The results obtained demonstrates the effectiveness of the proposed method for the detection of fQRS complexes with high sensitivity and low computational complexity.


Assuntos
Monitorização Fetal , Processamento de Sinais Assistido por Computador , Gravidez , Feminino , Humanos , Monitorização Fetal/métodos , Algoritmos , Feto/fisiologia , Eletrocardiografia/métodos
12.
Artigo em Inglês | MEDLINE | ID: mdl-38083436

RESUMO

Fetal electrocardiogram (fECG) or photoplethysmogram (fPPG) devices are being developed for fetal heart rate (FHR) monitoring. However, deep tissue sensing is challenged by low fetal signal-to-noise ratio (SNR). Data quality is easily degraded by motion, or interference from maternal tissues and data losses can happen due to communication faults. In this paper, we propose to combine fECG and fPPG measurements in order to increase robustness against such dynamic challenges and increase FHR estimation accuracy. To the author's knowledge the fusion of two sensory data types (fECG, fPPG) has not been investigated for FHR tracking purposes in the literature. The proposed methods are evaluated on real-world data captured from gold-standard large pregnant animal experiments. A particle filtering algorithm with sensor fusion in the measurement likelihood, called KUBAI, is used to estimate FHR. Fusion of PPG&ECG data resulted in 36.6% improvement in root-mean-square-error (RMSE) and 20.3% improvement in R2 correlation between estimated and reference FHR values compared to single sensor-type (PPG-only or ECG-only) data. We demonstrate that using different types of sensory data improves the robustness and accuracy of FHR tracking.


Assuntos
Frequência Cardíaca Fetal , Processamento de Sinais Assistido por Computador , Feminino , Gravidez , Animais , Monitorização Fetal/métodos , Fotopletismografia , Eletrocardiografia/métodos
13.
Artigo em Inglês | MEDLINE | ID: mdl-38083541

RESUMO

Monitoring the fetal heart rate (FHR) is common practice in obstetric care to assess the risk of fetal compromise. Unfortunately, human interpretation of FHR recordings is subject to inter-observer variability with high false positive rates. To improve the performance of fetal compromise detection, deep learning methods have been proposed to automatically interpret FHR recordings. However, existing deep learning methods typically analyse a fixed-length segment of the FHR recording after removing signal gaps, where the influence of this segment selection process has not been comprehensively assessed. In this work, we develop a novel input length invariant deep learning model to determine the effect of FHR segment selection for detecting fetal compromise. Using this model, we perform five times repeated five-fold cross-validation on an open-access database of 552 FHR recordings and assess model performance for FHR segment lengths between 15 and 60 minutes. We show that the performance after removing signal gaps improves with increasing segment length from 15 minutes (AUC = 0.50) to 60 minutes (AUC = 0.74). Additionally, we demonstrate that using FHR segments without removing signal gaps achieves superior performance across signal lengths from 15 minutes (AUC = 0.68) to 60 minutes (AUC = 0.76). These results show that future works should carefully consider FHR segment selection and that removing signal gaps might contribute to the loss of valuable information.


Assuntos
Aprendizado Profundo , Frequência Cardíaca Fetal , Gravidez , Feminino , Humanos , Frequência Cardíaca Fetal/fisiologia , Monitorização Fetal/métodos , Feto , Variações Dependentes do Observador
14.
Sci Rep ; 13(1): 19765, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37957257

RESUMO

Previous literature has highlighted the importance of maternal behavior during the prenatal period for the upbringing of healthy adults. During pregnancy, fetal health assessments are mainly carried out non-invasively by monitoring fetal growth and heart rate (HR) or RR interval (RRI). Despite this, research entailing prediction of fHRs from mHRs is scarce mainly due to the difficulty in non-invasive measurements of fetal electrocardiogram (fECG). Also, so far, it is unknown how mHRs are associated with fHR over the short term. In this study, we used two machine learning models, support vector regression (SVR) and random forest (RF), for predicting average fetal RRI (fRRI). The predicted fRRI values were compared with actual fRRI values calculated from non-invasive fECG. fRRI was predicted from 13 maternal features that consisted of age, weight, and non-invasive ECG-derived parameters that included HR variability (HRV) and R wave amplitude variability. 156 records were used for training the models and the results showed that the SVR model outperformed the RF model with a root mean square error (RMSE) of 29 ms and an average error percentage (< 5%). Correlation analysis between predicted and actual fRRI values showed that the Spearman coefficient for the SVR and RF models were 0.31 (P < 0.001) and 0.19 (P < 0.05), respectively. The SVR model was further used to predict fRRI of 14 subjects who were not included in the training. The latter prediction results showed that individual error percentages were (≤ 5%) except in 3 subjects. The results of this study show that maternal factors can be potentially used for the assessment of fetal well-being based on fetal HR or RRI.


Assuntos
Monitorização Fetal , Feto , Gravidez , Feminino , Adulto , Humanos , Monitorização Fetal/métodos , Feto/fisiologia , Eletrocardiografia/métodos , Cuidado Pré-Natal , Frequência Cardíaca Fetal/fisiologia
15.
Physiol Meas ; 44(11)2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-37939396

RESUMO

Objective.Independent component analysis (ICA) is widely used in the extraction of fetal ECG (FECG). However, the amplitude, order, and positive or negative values of the ICA results are uncertain. The main objective is to present a novel approach to FECG recognition by using a deep learning strategy.Approach.A cross-domain consistent convolutional neural network (CDC-Net) is developed for the task of FECG recognition. The output of the ICA algorithm is used as input to the CDC-Net and the CDC-Net identifies which channel's signal is the target FECG.Main results.Signals from two databases are used to test the efficiency of the proposed method. The proposed deep learning method exhibits good performance on FECG recognition. Specifically, the Precision, Recall and F1-score of the proposed method on the ADFECGDB database are 91.69%, 91.37% and 91.52%, respectively. The Precision, Recall and F1-score of the proposed method on the Daisy database are 97.85%, 97.42% and 97.63%, respectively.Significance. This study is a proof of concept that the proposed method can automatically recognize the FECG signals in multi-channel ECG data. The development of FECG recognition technology contributes to automated FECG monitoring.


Assuntos
Aprendizado Profundo , Processamento de Sinais Assistido por Computador , Feminino , Gravidez , Humanos , Monitorização Fetal/métodos , Algoritmos , Eletrocardiografia/métodos
16.
Pediatr Cardiol ; 44(8): 1726-1735, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37596420

RESUMO

To extract weak fetal ECG signals from the mixed ECG signal on the mother's abdominal wall, providing a basis for accurately estimating fetal heart rate and analyzing fetal ECG morphology. First, based on the relationship between the maternal chest ECG signal and the maternal ECG component in the abdominal signal, the temporal convolutional encoder-decoder network (TCED-Net) model is trained to fit the nonlinear transmission of the maternal ECG signal from the chest to the abdominal wall. Then, the maternal chest ECG signal is nonlinearly transformed to estimate the maternal ECG component in the abdominal mixed signal. Finally, the estimated maternal ECG component is subtracted from the abdominal mixed signal to obtain the fetal ECG component. The simulation results on the FECGSYN dataset show that the proposed approach achieves the best performance in F1 score, mean square error (MSE), and quality signal-to-noise ratio (qSNR) (98.94%, 0.18, and 8.30, respectively). On the NI-FECG dataset, although the fetal ECG component is small in energy in the mixed signal, this method can effectively suppress the maternal ECG component and thus extract a clearer and more accurate fetal ECG signal. Compared with existing algorithms, the proposed method can extract clearer fetal ECG signals, which has significant application value for effective fetal health monitoring during pregnancy.


Assuntos
Monitorização Fetal , Processamento de Sinais Assistido por Computador , Feminino , Gravidez , Humanos , Monitorização Fetal/métodos , Algoritmos , Simulação por Computador , Eletrocardiografia/métodos
17.
PLoS One ; 18(6): e0286858, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37279195

RESUMO

The independent component analysis (ICA) based methods are among the most prevalent techniques used for non-invasive fetal electrocardiogram (NI-fECG) processing. Often, these methods are combined with other methods, such adaptive algorithms. However, there are many variants of the ICA methods and it is not clear which one is the most suitable for this task. The goal of this study is to test and objectively evaluate 11 variants of ICA methods combined with an adaptive fast transversal filter (FTF) for the purpose of extracting the NI-fECG. The methods were tested on two datasets, Labour dataset and Pregnancy dataset, which contained real records obtained during clinical practice. The efficiency of the methods was evaluated from the perspective of determining the accuracy of detection of QRS complexes through the parameters of accuracy (ACC), sensitivity (SE), positive predictive value (PPV), and harmonic mean between SE and PPV (F1). The best results were achieved with a combination of FastICA and FTF, which yielded mean values of ACC = 83.72%, SE = 92.13%, PPV = 90.16%, and F1 = 91.14%. Time of calculation was also taken into consideration in the methods. Although FastICA was ranked to be the sixth fastest with its mean computation time of 0.452 s, it had the best ratio of performance and speed. The combination of FastICA and adaptive FTF filter turned out to be very promising. In addition, such device would require signals acquired from the abdominal area only; no need to acquire reference signal from the mother's chest.


Assuntos
Monitorização Fetal , Processamento de Sinais Assistido por Computador , Gravidez , Feminino , Humanos , Monitorização Fetal/métodos , Algoritmos , Feto , Eletrocardiografia/métodos
18.
Am J Obstet Gynecol MFM ; 5(9): 101068, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37380056

RESUMO

BACKGROUND: Nonreassuring fetal status detected by continuous electronic fetal monitoring accounts for almost 1 in 4 primary cesarean deliveries. However, given the subjective nature of the diagnosis, there is a need to identify the electronic fetal monitoring patterns that are clinically considered nonreassuring. OBJECTIVE: This study aimed to describe which electronic fetal monitoring features are most commonly associated with first-stage cesarean delivery for nonreassuring fetal status, and to evaluate the risk of neonatal acidemia following cesarean delivery for nonreassuring fetal status. STUDY DESIGN: This was a nested case-control study in a prospectively collected cohort of patients with singleton pregnancies at ≥37 weeks' gestation, admitted in spontaneous labor or for induction of labor from 2010 to 2014 at a single tertiary care center. Patients with preterm pregnancies, multiple gestations, planned cesarean delivery, or nonreassuring fetal status in the second stage of labor were excluded. Cases were identified as having nonreassuring fetal status on the basis of what was documented in the operative note by the delivering physician. Controls were patients without nonreassuring fetal status within 1 hour of delivery. Cases were matched to controls in a 1:2 ratio by parity, obesity, and history of cesarean delivery. Electronic fetal monitoring data were abstracted by credentialed obstetrical research nurses for the 60 minutes before delivery. The primary exposure of interest was the incidence of high-risk category II electronic fetal monitoring features in the 60 minutes before delivery; in particular, the incidence of minimal variability, recurrent late decelerations, recurrent variable decelerations, tachycardia, and >1 prolonged deceleration were compared between groups. We also compared neonatal outcomes between cases and controls, including fetal acidemia (umbilical artery pH <7.1), other umbilical artery gas analytes, and neonatal and maternal outcomes. RESULTS: Of the 8580 patients in the parent study, 714 (8.3%) underwent cesarean delivery for nonreassuring fetal status in the first stage of labor. Patients diagnosed with nonreassuring fetal status requiring cesarean delivery were more likely to have recurrent late decelerations, >1 prolonged deceleration, and recurrent variable decelerations compared with controls. More than 1 prolonged deceleration was associated with 6 times increased rate of nonreassuring fetal status diagnosis resulting in cesarean delivery (adjusted odds ratio, 6.73 [95% confidence interval, 2.47-8.33]). Rates of fetal tachycardia were similar between groups. Minimal variability was less common in the nonreassuring fetal status group compared with controls (adjusted odds ratio, 0.36 [95% confidence interval, 0.25-0.54]). Compared with control deliveries, cesarean delivery for nonreassuring fetal status was associated with nearly 7 times higher risk of neonatal acidemia (7.2% vs 1.1%; adjusted odds ratio, 6.93 [95% confidence interval, 3.83-12.54]). Composite neonatal morbidity and composite maternal morbidity were more likely among patients delivered for nonreassuring fetal status in the first stage (3.9% vs 1.1%; adjusted odds ratio, 5.70 [2.60-12.49]; and 13.3% vs 8.0%; adjusted odds ratio, 1.99 [1.41-2.80]). CONCLUSION: Although multiple category II electronic fetal monitoring features have been traditionally linked to acidemia, the presence of recurrent late decelerations, recurrent variable decelerations, and prolonged decelerations seemed to concern obstetricians enough to surgically intervene for nonreassuring fetal status. A clinical intrapartum diagnosis of nonreassuring fetal status in the setting of these electronic fetal monitoring features is also associated with increased risk of acidemia, suggesting clinical validity to the diagnosis of nonreassuring fetal status.


Assuntos
Cardiotocografia , Trabalho de Parto , Gravidez , Feminino , Recém-Nascido , Humanos , Sofrimento Fetal , Estudos de Casos e Controles , Monitorização Fetal/métodos
19.
Am J Obstet Gynecol MFM ; 5(8): 101053, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37328034

RESUMO

BACKGROUND: Previous studies have suggested that acute mood states may influence levels of fetal activity. Because the fetal nonstress test relies on markers of fetal activity to suggest fetal wellbeing, its interpretation may be affected by maternal mood. OBJECTIVE: This study sought to determine if there are differences in nonstress test characteristics between pregnant individuals with and without symptoms of mood disorder. STUDY DESIGN: In this prospective cohort study, we recruited pregnant individuals undergoing nonstress test in the third trimester and compared the results of the nonstress test between pregnant individuals with scores above and below the cutoff values on validated screening questionnaires for depression and anxiety symptoms, the Patient Health Questionnaire-9 (PHQ-9) and Generalized Anxiety Disorder 7-item scale (GAD-7). Demographic information was collected from each participant at the time of recruitment, and medical information was extracted from the electronic medical record. RESULTS: A total of 68 pregnant individuals were enrolled, 10 (15%) of which screened positive for perinatal mood disorders. There was no significant difference in means of time to reactivity (15.6 [4.8] minutes vs 15.0 [8.0] minutes, P=.77), number of accelerations (0.16/min [0.08] vs 0.16/min [0.10], P>.95), number of fetal movements (17.0 [14.7] vs 19.7 [20.4], P=.62), heart rate baseline (138.0 [7.5] bpm vs 139.2 [9.0] bpm, P=.67) or variability (8.5 [2.5] bpm vs 9.1 (4.3) bpm, P=.51) between pregnant individuals who screen positive for mood disorders and those who did not. CONCLUSION: Fetal heart rate patterns are similar in pregnant individuals with and without symptoms of mood disorder. The results provide reassurance that acute symptoms of anxiety and depression do not have significant effects on the fetal nonstress test.


Assuntos
Monitorização Fetal , Feto , Gravidez , Feminino , Humanos , Estudos Prospectivos , Monitorização Fetal/métodos , Feto/fisiologia , Ansiedade/diagnóstico , Ansiedade/epidemiologia , Ansiedade/etiologia , Transtornos de Ansiedade/diagnóstico , Transtornos de Ansiedade/epidemiologia , Transtornos de Ansiedade/etiologia
20.
Am J Obstet Gynecol MFM ; 5(7): 101001, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37146688

RESUMO

BACKGROUND: Electronic fetal monitoring is widely used to identify and intervene in suspected fetal hypoxia and/or acidemia. Category II fetal heart rate tracings are the most common class of fetal monitoring in labor, and intrauterine resuscitation is recommended given the association of category II fetal heart rate tracings with fetal acidemia. However, limited published data are available to guide intrauterine resuscitation technique selection, leading to heterogeneity in the response to category II fetal heart rate tracings. OBJECTIVE: This study aimed to characterize approaches to intrauterine resuscitation in response to category II fetal heart rate tracings. STUDY DESIGN: This was a survey study administered to labor unit nurses and delivering clinicians (physicians and midwives) across 7 hospitals in a Midwestern healthcare system spanning 2 states. The survey posed 3 category II fetal heart rate tracing scenarios (recurrent late decelerations, minimal variability, and recurrent variable decelerations) and asked participants to select first- and second-line intrauterine resuscitation management strategies. The participants were asked to quantify the level of influence certain factors have on their choice using a scale from 1 to 5. Intrauterine resuscitation strategy selection was compared by clinical role and hospital type (nurses vs delivering clinicians and university-affiliated hospital vs non-university-affiliated hospital). RESULTS: Of 610 providers invited to take the survey, 163 participated (response rate of 27%): 37% of participants from university-affiliated hospitals, 62% of nurses, and 37% of physicians. Maternal repositioning was the most selected first-line strategy, regardless of the type of category II fetal heart rate tracing. First-line management varied by clinical role and hospital affiliation for each fetal heart rate tracing scenario, particularly for minimal variability, which was associated with the most heterogeneity in the first-line approach. Previous experience and recommendations from professional societies were the most influential factors in intrauterine resuscitation selection overall. Of note, 16.5% of participants reported that published evidence did not influence their choice at all. Participants from a university-affiliated hospital were more likely than participants from a non-university-affiliated hospital to consider patient preference when selecting an intrauterine resuscitation technique. Nurses and delivering clinicians differed significantly in the rationale for management choices: nurses were more often influenced by advice from other healthcare providers on the team (P<.001), whereas delivering clinicians were more influenced by literature (P=.02) and ease of technique (P=.02). CONCLUSION: There was significant heterogeneity in the management of category II fetal heart rate tracing. In addition, motivations for choice in intrauterine resuscitation technique varied by hospital type and clinical role. These factors should be considered when creating fetal monitoring and intrauterine resuscitation protocols.


Assuntos
Monitorização Fetal , Trabalho de Parto , Gravidez , Feminino , Humanos , Monitorização Fetal/métodos , Cardiotocografia/métodos , Cuidado Pré-Natal , Atenção à Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...